Overview

Manipulate LEDs on IBM ppc64 platforms.

usysident

The usysident utility is used to view and manipulate the indicators (LEDs) that identify certain devices on PowerPC-64 machines. These identifiers are specified by location code; location codes can be retrieved by running lscfg.

When run without arguments, usysident will print a list of all of the identification indicators on the system along with their current status (on or off). The -l or -d options can be used to specify a particular indicator, by location code or logical device name respectively. If -l or -d is the only argument, the status of that indicator will be printed. If the -s argument is specified in addition, the indicator may be turned on or off.

usysattn

The usysattn utility is used to view and manipulate the attention indicators (LEDs) on PowerPC-64 machines. These indicators are turned on automatically when a serviceable event is received. These identifiers are specified by location code.

When run without arguments, usysattn will print a list of all of the attention indicators on the system along with their current status (on or off). The -l option can be used to specify a particular indicator. If -l is the only argument, the status of that indicator will be printed. If -s normal is specified along with the -l argument, the indicator will be turned off.

NOTE: Ensure that there are no outstanding service actions to be taken on this system before turning off the system attention indicators.